Flow Bench · Guide

What a flow bench number means for horsepower

A flow number says how much air a part passes at one steady pressure. An engine never breathes at one steady pressure. The number is where power starts, and this is how far it goes.

What it is

What a flow bench measures

A flow bench holds a fixed pressure difference across a part, the test pressure, and reports the air that passes. SuperFlow, which makes them, is plain about it: the bench does not measure flow directly, it compares the part with a reference orifice inside the machine. The result is a volume of air per minute at a stated test pressure, usually given in inches of water.

Two things follow. A number means nothing without its test pressure. And it describes a steady stream, drawn for as long as you like, through a part that is standing still.

Comparing two numbers

The same part reads higher at a higher test pressure

Flow rises with the square root of the test pressure. To compare a number taken at one pressure with a number taken at another, multiply by the square root of their ratio. This is the method the bench maker publishes with its machines.

FromToMultiply by
10 inches of water25 inches1.58
10 inches of water28 inches1.67
25 inches of water28 inches1.06

The rule moves a number between test pressures. It does not make two different benches agree, and it assumes the part behaves the same at both pressures. In Flow Bench's own runs the flow coefficient of every mouth rises a little as the pressure does.

Why it matters

More flow is where power starts

An engine makes power from the air it traps. In 1943 a NACA study changed the size, shape and lift of the inlet valve on a test engine and found that the engine's volumetric efficiency followed a single curve when plotted against a quantity built from the valve's steady flow coefficient. Its first conclusion was that the steady coefficient "was a useful measure of the actual coefficient under running conditions."

So a part that flows better on a bench has raised the ceiling. The bench maker says the same thing about its own horsepower rule of thumb: it estimates what the engine could make if everything else in the system were arranged to use the air.

Where it stops

A running engine does not draw a steady stream

The same NACA group wrote four years later that the validity of applying steady flow coefficients to the intermittent flow of an engine "at the highest crank speeds used here has not been established", while still finding them very useful. The valve opens and shuts, the air in the intake surges and rebounds, and how much is trapped depends on where that surge is when the valve closes.

A 2024 study shows how far the two can part. On a 1.8 liter four-cylinder aircraft engine, the authors compared the standard intake plenum with one 3.8 times its volume. In a steady flow test at full valve lift the larger plenum passed 9.1% more air. They then simulated the running engine, with a model checked against measurements on the standard plenum:

Computed volumetric efficiency (Anaclerio and others, 2024)
Engine speedStandard plenumLarger plenumDifference
5,000 rpm0.9400.8667.87% less
5,500 rpm0.9200.8675.76% less
5,800 rpm0.8970.8653.57% less

The part that flowed more filled the cylinder less at every speed studied. The authors' explanation is the pressure waves: the larger plenum damps them, so the pressure at the valve is lower in the last part of the intake stroke and less charge is trapped when the valve closes.

  • The 9.1% is at a valve lift of 12 mm, which is above that engine's own maximum of 10 mm.
  • The larger plenum's figures are computed. Only the standard plenum was measured on the engine.
  • The study reports volumetric efficiency, not torque or power.

In practice

What to do with a flow number

  • Rank parts with it. Same bench, same test pressure, same setup. That is what it is good at.
  • State the test pressure, and convert before comparing with anyone else's number.
  • Do not trade it for length or volume blindly. A change that adds flow by changing the intake's length or the airbox's volume has also moved the pressure waves. The stack length calculator shows where a length puts them.
  • Confirm on a dyno. Back to back, the same day, the stock part before and after the new one, so the dyno's own drift is visible.

Flow Bench reports a flow and a flow coefficient at a stated pressure ratio, and makes no horsepower claim without a dyno match behind it. The guide to the lip and its radius shows what its flow numbers look like for three mouths on one pipe.

For racing use only.

FAQ

Flow and power, answered

Short answers, with the sources above behind them.

Does more CFM on a flow bench mean more horsepower?

It means the part could let the engine breathe more. Whether the engine does depends on what the pressure waves in the intake do while the valve is open. A published study found a plenum that passed 9.1% more air in a steady test and computed 4% to 8% less volumetric efficiency for the running engine.

What test pressure should a flow number be quoted at?

Any, as long as it is stated and the two numbers you compare were taken at the same one. Benches are commonly run at 10, 25 or 28 inches of water. A number with no test pressure beside it cannot be compared with anything.

How do I convert a flow number from 10 inches of water to 28?

Multiply by the square root of the ratio of the two pressures. From 10 to 28 inches that is the square root of 2.8, or 1.67. From 10 to 25 it is 1.58, and from 25 to 28 it is 1.06. This is the method the bench maker SuperFlow publishes.

What is volumetric efficiency?

The air an engine actually takes in per cycle, divided by the air its displacement would hold at the density in the intake. At 0.90 the cylinder is trapping 90% of what its size could hold. It is the number that a running engine cares about, and a steady flow test does not measure it.

What pressure does Flow Bench run at?

Its published checks are at a pressure ratio of 1.04, which is a pull of about 16 inches of water, and its quick runs have been checked up to 1.20. A bench at 28 inches of water is at a pressure ratio of about 1.07.

Flow Bench

Flow Bench news

Flow Bench shows how your part flows, and the dyno match that holds it to your own pulls is next. It is in open beta: free to use, and you pay only for the runs you start. Leave an address for a short note when it adds something new.

Now check your email

A message is on its way with a link in it. Open that link and you are on the list. Nothing else gets sent until you do.

That did not come through with an email address in it. Try once more.

That is several signups from one connection in a row. Wait a minute and try again.

Advertisement
Fund the next leg